Radiation-free CT-like bone imaging using UTE (ultrashort echo-time) MRI A fast 2-minute multi-echo ultrashort echo-time (UTE) MRI acquisition, combined with deep learning-based reconstruction, enables a comprehensive MRI-only musculoskeletal exam in under 10 minutes, according to the researchers behind the work. The approach produces CT-like bone-weighted contrast plus quantitative T2* mapping of short-T2 tissues such as tendons, ligaments and menisci, which standard MRI shows only as signal voids until later stages of injury. The authors cite Huang et al. in Clinical Imaging (2025), which reported extremity MRI reimbursement fell up to 77% in 2025 versus its 2004 peak, as motivation for faster scans that could spare pediatric, pregnant and repeat-imaging patients a CT scan and its ionizing radiation. Fast MRI-only Comprehensive Musculoskeletal Imaging Seeing the previously unseen. Reducing cost, streamlining workflow, and eliminating ionizing radiation exposure. Both MRI and CT are traditionally required for comprehensive evaluation of soft tissue and bony structures. However, advances in MRI, including multi-echo ultrashort echo time UTE , conjugate-gradient SENSE, and deep learning–based reconstruction, now enable a comprehensive MRI-only musculoskeletal MSK examination in under 10 minutes. This reduces cost, streamlines clinical workflow, and eliminates ionizing radiation exposure, especially important for pediatric and pregnant patients and for individuals requiring repeated CT imaging. Latest News YouTube https://youtu.be/-c1TVBGnxXM directly if the video does not load . YouTube https://youtu.be/YLaz4P1-KOs directly if the video does not load . This work addresses three interrelated challenges in musculoskeletal MSK imaging. Economic trends First , Medicare and Medicaid reimbursement for MRI has steadily declined. Huang et al. Clinical Imaging, 2025 reported that reimbursement for extremity MRI in 2025 has decreased by up to 77% compared with its peak in 2004. These economic pressures motivate the development of faster MSK MRI examinations. Gaps in clinical MSK imaging Second , short-T2 tissues including tendons, ligaments, and menisci are poorly visualized by CT and they are indirectly visualized as signal voids by standard-of-care routine MSK MRI, until relatively late stages of injury or disease, when they appear hyperintense or morphologically deformed on conventional MRI. Earlier visualization and quantitative assessment of short-T2 tissues would enable not only earlier detection but also more objective evaluation of disease progression and treatment response. Clinical needs Third , when comprehensive assessment of both bone and soft tissue is required, patients typically undergo both CT and MRI examinations. Although MRI may not fully replace CT, MRI-derived CT-like bone-weighted images can, when appropriate, obviate the need for a CT scan, thereby streamlining clinical workflow, reducing costs, and eliminating ionizing radiation exposure, particularly important for pediatric and pregnant patients and for individuals requiring repeated CT imaging. Current states Zero-echo-time ZTE and single-echo ultrashort-echo-time UTE techniques have demonstrated the ability to provide CT-like bone-weighted contrast; however, they do not provide assessment of short-T2 tissues. Multi-echo UTE allows simultaneous generation of CT-like contrast and quantitative T2 mapping of short-T2 tissues, but its clinical adoption has been limited because of long scan times and insufficient spatial resolution. Our proposed solution In this work, we demonstrate the feasibility of a fast, 2-minute multi-echo UTE acquisition that provides CT-like bone-weighted contrast and quantitative T2 mapping of short-T2 tissues. With the integration of deep learning-based reconstruction MRI-DLR https://hdocmsu.github.io/projects/canon 1 dlr/ , routine MSK MRI can be completed in under 8 minutes. Together, this enables a comprehensive MRI-only MSK examination in under 10 minutes. A vision for the future Total scan time can be further reduced by combining a 2-minute multi-echo UTE acquisition with an abbreviated musculoskeletal MSK MRI protocol, in which sequences are selected to maximize diagnostic yield per unit scan time. The abbreviated MSK-MRI protocol is indication-specific and can be completed in well under 3 minutes. Together, this approach enables a comprehensive, MRI-only MSK examination in under 5 minutes. As a result, a single MRI-only exam can provide information traditionally obtained from both MRI and CT, while achieving CT-like throughput. This capability has the potential to position MRI as a first-line imaging modality, particularly by reducing or eliminating the need for subsequent MRI and/or CT examinations. Preprint under peer review - HP Do , et al. "Accelerated 2-Minute Multi-Echo UTE MRI for Simultaneous CT-Like Bone Imaging and Quantitative Short-T2 Mapping." medRxiv 2026.08.18.26360232; doi: \ 10.64898/2026.08.18.26360232\ https://doi.org/10.64898/2026.08.18.26360232 Software tutorial - HP Do Feb. 08, 2026 . "cgsense2023: A Step-by-Step Tutorial to Conjugate Gradient Sensitivity Encoding CG-SENSE MRI." Zenodo. doi: \ 10.5281/zenodo.18526383\ https://doi.org/10.5281/zenodo.18526383 \ PyPI Project Page\ https://pypi.org/project/cgsense2023/ Educational poster - HP Do , et al. "Radial MRI: Characteristic Artifacts and Clinical Applications for 2-Minute Simultaneous CT-Like Bone Imaging and T2 Mapping." Proceedings of the Radiological Society of North America Education Exhibits, Chicago, Dec 2026 Whitepaper - HP Do . "Good to Know: Multi-echo Ultrashort Echo Time UTE ." Canon Medical Systems Corporation, Japan, Mar 2022. \ PDF\ https://hdocmsu.github.io/assets/pdf/whitepapers/G2K UTE final.pdf \ HTML\ https://global.medical.canon/products/magnetic-resonance/good-to-know ultrashort Peer-reviewed publications and talks: - HP Do , et al. "Two-minute Multi-Echo UTE for Simultaneous CT-like Bone-weighted Imaging and Quantitative T2 Mapping.” The Radiological Society of North America RSNA Scientific Session, Chicago, Nov 2026. - HP Do , et al. "Accelerated 1.2-minute 4-echo UTE-based CT-like Imaging using CG-SENSE and Deep Learning-based Denoising Reconstruction DLR .” International Society for Magnetic Resonance in Medicine Scientific Meeting, Hawaii, May 2025. \ SLIDES-PDF\ https://hdocmsu.github.io/assets/pdf/slides/HungDo ismrm25 ute talk.pdf \ VIDEO-YouTube\ https://youtu.be/VUuOUfhyGZk - HP Do , et al. "Accelerated 2-3-Minute Multi-echo Ultra-short Echo Time mecho UTE using Conjugate Gradient SENSE CG-SENSE Reconstruction.” The Radiological Society of North America RSNA Scientific Session, Chicago, Nov 2023. \ SLIDES-PDF\ https://hdocmsu.github.io/assets/pdf/slides/HungDo rsna23 talk ute cgsense rev5.1 toHTML.pdf \ VIDEO-YouTube\ https://youtu.be/i2oL1sIr0x8 - HP Do , et al. "Eleven-minute Comprehensive MSK Imaging Using Deep Learning Reconstruction DLR and Multi-echo Ultrashort Echo-Time UTE ." The Radiological Society of North America RSNA Scientific Session, Chicago, Nov 2022. \ SLIDES-PDF\ https://hdocmsu.github.io/assets/pdf/slides/HungDo rsna22 talk rev4.0 web.pdf High-level overview Here https://hdocmsu.github.io/assets/proj/canon 2 ute/ute review.pdf is the high-level overview of this project. Get future posts delivered to your inbox.