Predicting Fluid Behavior Before the Lab: Physics-Based Screening From AI Data Centers to… An independent researcher published open-source screening models on GitHub (fluids-heat-vacuum) that use published data and textbook physics to predict fluid behavior for immersion-cooled GPU racks and spacecraft vacuum applications, backed by 26 unit tests. For immersion cooling, an NSGA-II search over blends of up to three base stocks from eleven published stocks found three blends meeting the Open Compute Project base spec at worst-case permittivity, with the lead blend cooler than the PAO benchmark in 97% of 300 Monte Carlo draws and cheaper to pump in 97%; pumping was found to cost about 2% of IT power, or roughly $20,000–34,000 per MW a year. For space, the model drew on NASA Goddard's ASTM E595 database of 12,842 tests from 1,476 manufacturers, in which 54% of tests fail, and found vacuum-baked materials pass 69% of the time versus 45% otherwise. Disclosure : I used AI tools to help structure and edit this article. The models, code, data and results are my own. An immersion-cooled GPU rack and a satellite in hard vacuum look like opposite problems. One fluid bathes 1 kW chips at 40 °C. The other must not evaporate onto optics over 15 years in orbit. Both come down to one question: will this fluid behave where we need it? In both fields, that question gets answered the slow way. You blend, test, fail and repeat. I built open screening models for both problems instead, from published data and textbook physics, so the lab only sees candidates with a real chance. All code, data and 26 unit tests are on GitHub fluids-heat-vacuum https://github.com/shehanmakani/fluids-heat-vacuum . This article walks through both studies: what I modeled, what the models found, and which assumptions mattered most. Both fields lean on fluorinated fluids, and both are being pushed off them. Many high-performance immersion coolants are fluorinated. Space mechanisms run on perfluoropolyether PFPE oils, and a 2025 ESA project reported that no fully PFAS-free space grease yet exists. Each field also has a hard pass/fail spec. Immersion cooling Open Compute Project base spec 4 : Vacuum ASTM E595 5 : The common thread is that vapor pressure, molar mass and viscosity decide most of the outcome. You can model those from published data before anyone opens a bottle. The goal was a non-fluorinated fluid that meets the OCP spec and beats a polyalphaolefin PAO benchmark. I started from eleven published base stocks: PAOs, synthetic esters, a natural ester, a mineral oil and a renewable isoparaffin. Every value in the data file is tagged as data sheet, estimate or proxy. Each blend runs through four layers of open models: The chip model held the first surprise. Flow in the fin channels is laminar, at a Reynolds number of about 16, so thermal conductivity and volumetric heat capacity dominate and viscosity barely matters. The turbulent figure of merit I used in round 1 misranked the fluids, so I retired it. The second surprise came from the facility model. I had first treated pumping as negligible. It is about 2% of IT power, or roughly $20,000–34,000 per MW a year depending on the fluid. That turned viscosity back into a real cost, just at the pump instead of the chip. I searched blends of up to three stocks, each at least 5%, with a multi-objective evolutionary optimizer NSGA-II 1 under the OCP limits. The objectives were chip cooling, pumping cost and the biodegradable share. Three blends pass the spec at worst-case permittivity. Here they are against the PAO benchmark PAO 4 88% + PAO 2 12%, worst-case dielectric constant 2.08 : The all-ester blend is the best thermally but fails the 2.3 dielectric limit. That points to the one number that governs the whole design: ester permittivity at 20–40 GHz is unpublished. Esters measure about 3 at 100 kHz, and the value falls at GHz by an unknown amount. That gap alone sets how much ester a blend can carry. To check how robust the leads are, I ran 300 Monte Carlo draws on the property inputs and sampled ester permittivity anywhere from 2.2 up to its low-frequency value. Lead A came out cooler than PAO in 97% of draws and cheaper to pump in 97%. The all-ester blend met the dielectric limit in only 5%. I then re-ran the search independently on IntelliForm’s NSGA-III and TOPSIS engine 2 . Without being given the earlier answer, it found 35 Pareto blends. Its coolest fully biodegradable blend matched Lead G to within one percentage point. Anything flown on a spacecraft must pass ASTM E595: 24 hours at 125 °C in vacuum, with a 25 °C plate collecting whatever evaporates. NASA Goddard publishes every result 3 . After cleaning, the database holds 12,842 tests from 1,476 manufacturers. 54% of them fail. Process matters as much as chemistry: vacuum-baked materials pass 69% of the time against 45% otherwise. In 12 product families tested both ways, baking raised the pass rate from 1% to 59%. I tried two ways to predict the result before testing. A statistical model. A logistic regression on material class, usage, manufacturer, process flags and character n-grams of the product name. Cross-validated by product family, so the same product never sits in both train and test, it reaches AUC 0.81 and 74% accuracy. Testing only the top 30% of its picks raises the pass rate from 46% to 79%. The ceiling is real, though: repeat tests of the same family agree with each other only 86% of the time, and the database records trade names, not compositions. A physics model. The E595 sample cup behaves like an effusion cell. My simulator integrates evaporation through the exit port Hertz–Knudsen flux at each component’s Raoult partial pressure , capture on the collector, and re-evaporation from it. Nothing is fitted to the test results. Across five reference fluids spanning more than a 100,000-fold range in vapor pressure, it predicts total mass loss within a factor of 2.5. The physics model also yields a design rule for a single low-volatility fluid. It needs only two properties: vapor pressure at 125 °C and molar mass. python import math python def passes e595 p 125c pa, molar mass kg mol : """Screening rule for a single low-volatility fluid linear-loss regime .""" x = p 125c pa math.sqrt molar mass kg mol return {"TML <= 1%": x < 1.9e-4, "CVCM <= 0.10%": x < 2.3e-5} the CVCM limit binds first That rule turns a 24-hour vacuum test into a target a molecule designer can aim at. It also connects back to lubricants: a PFAS-free oil that works at −40 °C and evaporates slowly enough for a 15-year mission would pass E595 comfortably. These are screening models, not certification. Oxidation stability, materials compatibility and breakdown voltage still need the lab, as do closed-cup flash points. What the models do is shrink the lab plan to a few measurements that matter: ester permittivity at GHz, closed-cup flash and pour point for three leads, and E595 runs on candidates that already clear the design rule. A GPU rack and a satellite ask the same question of a fluid. Open data and textbook physics answer most of it before the first experiment. You can explore the blends yourself in the browser-based Fluid Selector https://shehanmakani.github.io/fluids-heat-vacuum/ , which reproduces the Python models to within 0.01%. The code is on GitHub https://github.com/shehanmakani/fluids-heat-vacuum . 1 K. Deb, A. Pratap, S. Agarwal and T. Meyarivan, “A fast and elitist multiobjective genetic algorithm: NSGA-II,” IEEE Trans. Evol. Comput. , vol. 6, no. 2, pp. 182–197, 2002. 2 S. S. Makani, “From Benchmark to Production: A Surrogate-Assisted Multi-Objective Optimization Framework for Industrial Chemical Formulation at Scale,” Digital Discovery , Royal Society of Chemistry, 2026, doi: 10.1039/D6DD00112B. 3 NASA Goddard Space Flight Center, “Spacecraft Material Outgassing Data,” data.nasa.gov. 4 Open Compute Project, “Base Specification for Immersion Fluids.” 5 ASTM International, ASTM E595, “Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment.” Predicting Fluid Behavior Before the Lab: Physics-Based Screening From AI Data Centers to… https://pub.towardsai.net/predicting-fluid-behavior-before-the-lab-physics-based-screening-from-ai-data-centers-to-9bddc5b14487 was originally published in Towards AI https://pub.towardsai.net on Medium, where people are continuing the conversation by highlighting and responding to this story.