FlowScope: 3D Scene Flow Pretraining Improves Surgical Robot Policies FlowScope, a pretraining method that forecasts metric 3D scene flow from unlabeled stereo surgical video, raised needle pickup success on a real surgical robotic system from 54% to 90% and first-handover success on needle regrasp from 4% to 52%, according to the arXiv paper 2611.26865v1. The authors pretrained the trunk of an Action Chunking Transformer on 1,149 clinical procedures (1.35M clips) using labels computed by off-the-shelf stereo depth and optical flow models, then discarded the flow head so the deployed policy is a standard ACT with no added inference cost. Full-task success rose from 2% to 14% over training from scratch (n=50 trials each), and ablations found metric 3D motion the strongest pretraining signal tested, outperforming kinematics, 2D tracks, depth alone, and scale-free 3D flow. arXiv:2611.26865v1 Announce Type: new Abstract: Imitation learning for surgical robots is limited by the cost of collecting demonstrations. Meanwhile, many robot-assisted procedures are recorded as stereo video, yet policies cannot learn from them directly; clinical video carries no action labels. We present FlowScope, which pretrains a surgical policy network on unlabeled clinical video by forecasting scene flow, the metric 3D motion of scene points, with labels computed by off-the-shelf stereo depth and optical flow models. We pretrain the trunk of an Action Chunking Transformer ACT on a dataset of 1,149 clinical procedures 1.35M clips and discard the flow head afterward, so the deployed policy is a standard ACT with no added inference cost. On a real surgical robotic system, FlowScope raises needle pickup success from 54% to 90% and first-handover success on needle regrasp from 4% to 52% full task: 2% to 14% over training from scratch n=50 trials each , and retains its gains with a generative flow-matching action head. Ablations indicate that metric 3D motion is the strongest pretraining signal among those tested; kinematics, 2D tracks, depth alone, and scale-free 3D flow, each paired with kinematics, yield smaller or no gains. Representation analyses suggest that scene-flow pretraining encodes metric needle depth more accurately, that kinematics pretraining increases reliance on the robot state, and that needle-depth probes follow the ordering of real-robot success where offline validation error does not.