arXiv:2610.31993v1 Announce Type: cross Abstract: AI models already inform clinical decisions and draft notes in Australian clinical software, usually without the practitioner being told which model is used. Existing medical benchmarks are written for other jurisdictions. We wrote 142 questions from Australian guidelines and schedules across five domains (PBS authority, MBS billing, Ahpra obligations, triage red flags, immunisation and screening), each with one verifiable answer scored by exact match. Each question ran blind and with the governing clause supplied, which separates failure to recall the current rule from failure to apply it. We tested 28 models between July and October 2026. Blind accuracy ranged from 51.5% to 92.7%, and the highest-scoring models could not be separated. Of 791 failed model-question pairs, 684 (86%) were wrong blind and right with the clause. Confident-error rates ranged from 6.6% to 47.8%. On five immunisation questions where the guideline gives no directive, 82% of answers stated one. On 20 Aboriginal and Torres Strait Islander health questions, models did no worse overall, but on a few the wrong answers gave the rule for the general population, an older rule or another country's rule. We propose treating the model as an ingredient of a clinical product, with a minimum standard on local rules that sits beside product evaluation. The keys are one general practitioner's and are not yet independently reviewed. The benchmark measures base models, not clinical products, and does not license any model for clinical use.
AusClinBench: a deterministically scored benchmark of large language models against current Australian clinical policy
A new benchmark, AusClinBench, found that 28 large language models tested between July and October 2026 scored between 51.5% and 92.7% blind accuracy on 142 questions drawn from Australian clinical guidelines and schedules, with the top models statistically indistinguishable. Of 791 failed model-question pairs, 684 (86%) were wrong blind but correct when the governing clause was supplied, and confident-error rates ranged from 6.6% to 47.8%. On five immunisation questions where the guideline gives no directive, 82% of answers nonetheless stated one, and the authors propose treating the model as an ingredient of a clinical product with a minimum standard on local rules; the question keys come from one general practitioner and have not been independently reviewed.
Run your AI side-project on zahid.host
EU-based hosting, git-push deploys, automatic HTTPS, no cold starts. Free tier with a custom domain — perfect for shipping the agent you just read about.